Beta Series

The Beta series digital panel meters offers 3 displays and a large number of input options.

A range of output options are available including;
2 x SPST, 8A relays
4 x SPDT, 5A relays
4 x NPN
4 x PNP
RS-232 or RS-485
Analogue outputs – 0-10VC & 4-20mA
BCD

 

 

BETA-D is designed for counting and totalising applications or as tachometer with totaliser which accepts pulse signals generated by a wide range of sensors. In the tachometer-totaliser mode it is possible to measure the velocity in programmable units, Flow and the accumulated total at the same time as Cost.

Outstanding characteristics:

• Bi-directional counter with fase squaring X1, X2, X4.
• Independent multiplying factor per each channel.
• 2 physical inputs and 1 virtual input.
• Independent programming of unit/batch on each channel.
• Arithmetic operations between channels (+, -, x, / and %)
• Up to 3 totalizers.
• Tachometer with spinning direction indication.
• Setpoint programming direct access.
• 27 logical functions user programmable.
• Latch or Pulse relay function.
• ModBus RTU protocol.
• Batch counter per each channel.
• Slow-Down function.
• Track-auto function.
• Programming lockout by software (13 levels).

DATA SHEET

TECHNICAL MANUALS

Part 1 Part 2

The BETA-M is a digital multi-function instrument with input options are programmable:

• Process variables (mV, V, or mA)
• Pt100 Temperature sensors or Thermocouples J, K, T, R, S, E.
• Weight, load, force, torque with bridge sensor up to ±300mV.
• Displacement, linear potentiometer.
• 29 logical functions user selectables.
• Two kind of filters with 10 leves
• Average up to 200 readings.
• 3 rate of display.

DATA SHEET

TECHNICAL MANUALS

Part 1 Part 2

Building on the excellent performance the Beta-M technology, the Beta-MP adds the ability to program up to 8 different configurations that allows the use of 8 sensors with different calibrations. The change of sensor is accessible by keyboard or logic functions. Useful for materials testing laboratories where sensors have different ranges, sensitivities, that have been previously calibrated and saved in the Beta-MP.

• Process variables (mV, V, or mA)
• Pt100 Temperature sensors or Thermocouples J, K, T, R, S, E.
• Weight, load, force, torque with bridge sensor up to ±300mV.
• Displacement, linear potentiometer.
• 29 logical functions user selectables.
• Two kind of filters with 10 leves
• Average up to 200 readings.
• 3 rate of display.

DATA SHEET

TECHNICAL MANUALS

Part 1 Part 2